Section 360-381-202
Equipment Issue 2
Fourth Printing, December 2006
Telecommunications Group
2006 Charles Industries Ltd.
All rights reserved. Printed in United States of America.
The availability of features and technical specifications herein subject to change without notice.
Page 1 of 17
T1 Controller with SNMP (3603-81)
CONTENTS PAGE
Part 1. GENERAL 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 2. INSPECTION 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 3. APPLICATION GUIDELINES 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 4. TIMESLOT ALLOCATION 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 5. INSTALLATION 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 6. OPTIONING 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 7. ALARMS 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 8. NETWORK MANAGEMENT 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 9. TECHNICAL ASSISTANCE 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 10. WARRANTY & CUSTOMER SERVICE 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part 11. SPECIFICATIONS 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRI
3603−81
AR AY
TP LP
MON
RCV XMT
ACO
MGMT
ADDRESS
ID PWR
+
TI
Figure 1. 3603-81 T1 Controller Unit Front Panel
Vista de pagina 0
1 2 3 4 5 6 ... 16 17

Indice de contenidos

Pagina 1

Section 360-381-202Equipment Issue 2Fourth Printing, December 2006Telecommunications Group2006 Charles Industries Ltd.All rights reserved. Printed in

Pagina 2 - 1. GENERAL

Section 360-381-202105.1.2. Installing a New UnitUse the following steps to install the T1-S.Step Action1. If not already installed, install the rear

Pagina 3

Section 360-381-20211Table 1. LED DefinitionsLabel Color Status Indicates that...POWER Green ON The unit is receiving power.OFF The unit is not power

Pagina 4 - 3. APPLICATION GUIDELINES

Section 360-381-20212Table 3. RJ48 T1 Jack PinoutsPin # Use1 R (RCV from network)123456782 T (RCV from network1 2 3 4 5 6 7 83 —4 R1 (XMT to network)

Pagina 5

Section 360-381-202136.2 Software OptioningThis unit comes from the factory with default provisioning, which can be changed through the Network Manage

Pagina 6

Section 360-381-20214T1 restore to Red Alarm retired 15 Sec. 1 Sec. 1 Sec.Yellow alarm detected to declared < 1 Sec. < 1 Sec. < 1 Sec.Yellow

Pagina 7 - 4. TIMESLOT ALLOCATION

Section 360-381-20215Operations Channel (EOC), if the T1 is utilizing EFS format, or can utilize a timeslot in the T1. This is donethrough the optioni

Pagina 8

Section 360-381-202162. Include the following information:− Company name and address− Contact name and phone number− Inventory of equipment being ship

Pagina 9 - 5. INSTALLATION

Section 360-381-20217Parameter SpecificationT1 connector (rear panel.) RJ48PC control interface:Two types of connectors. (RS232 with RJ11 onthe front

Pagina 10

Section 360-381-20221. GENERAL1.1 Document PurposeThis document provides general, installation and testing information for the T1 Controller Unit (T1-

Pagina 11

Section 360-381-2023 Temperature hardened (−40 to +65 C) Combines the functions of a LIU and a CSU, allowing direct connections to public T1 network

Pagina 12 - 6. OPTIONING

Section 360-381-2024 Remote terminal status in a CO/RT configuration Tone/pattern test generator and error detection1.9 LoopbacksThe T1-S provides t

Pagina 13 - 7. ALARMS

Section 360-381-2025face to a powered line that uses line-powered repeaters. See Figure 2 and Figure 3 for typical applications. Otherapplications use

Pagina 14 - 8. NETWORK MANAGEMENT

Section 360-381-2026Figure 3 shows a similar application, except the DS1 facility is fractional “T1”. The 360-80 ICB maps the physicalslots into the f

Pagina 15 - 9. TECHNICAL ASSISTANCE

Section 360-381-2027(east). The data/voice on the Primary T1 can be “dropped” to any one of the cards in the 360-80. Any data/voicethat is not “droppe

Pagina 16 - 11. SPECIFICATIONS

Section 360-381-2028When a new channel card is installed in the system or a system reset to factory default values is performed, thedefault timeslot a

Pagina 17

Section 360-381-2029PrimaryT1Timeslot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17